Development and validation of a new electrical risk assessment method for the prevention and mitigation of damage to people and installations

Authors

  • Ronaldo López Serrazina Universidad Católica del Norte
  • Jaime Jiménez Ayala Universidad Politécnica de Valencia
  • Joaquín Catalá Alis Universidad Politécnica de Valencia

Keywords:

Risk’s evaluation, specific method, electrical hazards

Abstract

The risk assessments carried out to date, and the implementation of controls are only sometimes effective due to their lack of specificity. Therefore, this work aimed to develop a specific method to evaluate the probability and consequences of shock and electric arc hazards, adding a variable that considers the personal factor. The equation was formulated using the methods recommended by ISO 31010 for probability and consequence, including the human reliability of the same standard. The recommendations of the NFPA 70E standard were used to define the criteria for each variable. For the inclusion of controls, the principles of the Bow Tie method recommended in the ISO 31010 standard were used since the proposed matrix considered preventive, mitigating, and personal controls separately. The proposed method was evaluated and validated, which demonstrated the usefulness of the model since it allowed to assess the electrical risks with specific criteria, including the personal factor variable and the application of the proposed controls to reduce said risks, which that will directly benefit exposed workers and companies that use it.

Downloads

Download data is not yet available.

Author Biographies

Ronaldo López Serrazina, Universidad Católica del Norte

Universidad Católica del Norte. Escuela de prevención de Riesgos y Medio Ambiente. Coquimbo, Chile.

Universidad Politécnica de Valencia. Escuela de Doctorado. Email: rolo4@upv.es

Jaime Jiménez Ayala, Universidad Politécnica de Valencia

Universidad Politécnica de Valencia. Escuela Técnica Superior de Ingeniería de Caminos, Canales y Puertos.

EDEM Escuela de Empresarios, Centro adscrito a la Universidad Politécnica de Valencia. Grado en ingeniería y Gestión Empresarial. Email: jjimenez-ayala@edem.es

Joaquín Catalá Alis, Universidad Politécnica de Valencia

Universidad Politécnica de Valencia. Escuela Técnica Superior de Ingeniería de Caminos, Canales y Puertos.

Published

2024-12-19

How to Cite

[1]
R. López Serrazina, J. Jiménez Ayala, and J. Catalá Alis, “Development and validation of a new electrical risk assessment method for the prevention and mitigation of damage to people and installations”, Ingeniare, Rev. chil. ing., vol. 31, Dec. 2024.

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.